ENERGY STAR 7.0 is the rulebook a window has to pass before it can carry the blue label, and you can check every number in it yourself. Here’s how to find your zone, read the criteria, decode the label and match it all to your quote.
Version 7.0 check
Montgomery and Miami counties sit in the Northern zone, where an ENERGY STAR 7.0 window needs a U-factor of 0.22 or lower and an SHGC of at least 0.17, or a trade-off pair. Confirm the model in the NFRC and ENERGY STAR directories, and get those numbers on your quote.
Read time · 8 minutesFind Your Zone Before Any Number
ENERGY STAR 7.0 rules change by climate zone, so start with the ENERGY STAR climate zone finder: pick Windows, Doors or Skylights, choose Ohio, then your county. The result page for Montgomery County lists the zone and its criteria. Three Ohio lookups:
- Montgomery County, OHNorthern zone
- Miami County, OHNorthern zone
- Lawrence County, OHNorth-Central zone
That last line matters. In North-Central, a window needs a U-factor of 0.25 or lower, and SHGC is capped at 0.40 instead of held above a floor. Everything below uses Northern zone numbers.
Read the ENERGY STAR 7.0 Criteria Like a Spec Sheet
The full ENERGY STAR 7.0 specification is a public EPA document. For a Northern zone home, the part that matters fits in one table.
Why a minimum SHGC? In a heating climate, sun through the glass is winter heat the furnace doesn’t have to make. The trade-off rows push that logic further: accept a little more heat loss, and let in more winter sun to make up for it.
| Product (Northern zone) | Requirement | What it tells you |
|---|---|---|
| Windows: main path | U ≤ 0.22 · SHGC ≥ 0.17 | Low heat loss, some winter sun. |
| Windows: trade-off | U 0.23–0.24 · SHGC ≥ 0.35 | More heat loss, offset by more sun. |
| Windows: trade-off | U 0.25–0.26 · SHGC ≥ 0.40 | A larger trade. |
| Doors, more than half glass | U ≤ 0.26 · SHGC ≤ 0.40 | SHGC becomes a ceiling. |
| Doors, half glass or less | U ≤ 0.23 · SHGC ≤ 0.23 | Sliding and swinging doors. |
| Opaque doors | U ≤ 0.17 | No glass, so no SHGC rating. |
| Skylights | U ≤ 0.45 · SHGC any | Sloped glass. |
| Air leakage | ≤ 0.3 · doors ≤ 0.5 | cfm per square foot. |
Two details trip people up. Trade-off rows apply only to Northern zone windows, not doors or skylights. And a model must meet the specification in effect on its date of manufacture: the day the unit is completely assembled.
Does Your Window Pass ENERGY STAR 7.0?
Pick the U-factor and SHGC your quote lists to see which ENERGY STAR 7.0 path, if any, the window meets.
U-factor on the paperwork
SHGC on the paperwork
Decode the NFRC Label in Five Lines
ENERGY STAR 7.0 doesn’t take a manufacturer’s word for it. Ratings must be independently tested, certified and verified under National Fenestration Rating Council procedures, then printed on the NFRC label.
- UU-FactorHeat flow through the unit. Lower is better.Qualifies
- SHSHGCShare of the sun’s heat that gets through, from 0 to 1.Qualifies
- VTVisible TransmittanceDaylight that gets through, 0 to 1.Compare
- ALAir LeakageAir through the unit. Lower means fewer drafts.Capped
- CRCondensation ResistanceScored 0 to 100. Higher resists moisture better.Compare
Qualification rests on U-factor and SHGC, with air leakage held under its cap; VT and condensation resistance help you compare two qualifying windows. The Department of Energy notes that a VT below 0.5 noticeably cuts daylight, so check VT beside a very low SHGC. Our window performance ratings guide goes deeper on each line.
Look Up the ENERGY STAR 7.0 Listing in Two Directories
A label on a showroom sample proves the sample. To confirm the model on your quote, check two public databases.
ENERGY STAR Product Finder
- Open the certified windows, doors and skylights finder.
- Choose the product category, then enter your ZIP code or climate zone.
- Narrow by manufacturer and compare U-factor and SHGC with your quote.
NFRC Certified Products Directory
- Open the NFRC directory search.
- Search with the manufacturer and product details from the NFRC label.
- Confirm the listed ratings match the label line for line.
If the label and both directories agree, the rating is real. Can’t find the model? Ask for the exact series and glass package. One series can offer several glass options, such as coatings, gas fills or a third pane, each with its own rating.
Don’t panic over a missing sticker. The Department of Energy’s window purchasing guidance notes some qualifying products aren’t marked. The directory settles it.
Make the Quote, Label and Directory Match
Accountants approve an invoice only when the order, receipt and bill agree. Window paperwork works the same way: when all three line up and pass your zone, the ENERGY STAR 7.0 claim is confirmed.
Model and numbers
Series and glass package for each opening, with U-factor and SHGC as numbers, not just a logo.
Certified ratings
The same series and glass, with certified U-factor, SHGC and air leakage.
A matching listing
A listing whose ratings agree with the label and pass your county’s criteria.
- “ENERGY STAR” with no numbers. Ask for the U-factor and SHGC of each window.
- One rating for the whole house. Windows, patio doors and skylights each have their own criteria.
- Numbers from a different glass package. The rating must match the glass being priced.
- A trade-off rating on a door. Those rows cover windows only.
- A window rated for another zone. A U-factor of 0.25 with SHGC 0.30 meets North-Central but misses the Northern zone.
Comparing Nobility windows? Thrush & Son installs Nobility, and the same check applies: get the NFRC ratings for the series and glass package on each opening, then run them through the board. Our Nobility windows guide covers the lineup.
The Takeaway Worth Sharing
ENERGY STAR 7.0 is checkable. Find the zone, match the numbers, and let the directory settle it.
Send this to anyone holding a window quote before the first hard freeze.
Want the Ratings Checked? Let’s Do It Together
Thrush & Son®: family-owned exterior pros since 1960.
If you’re in the Miami Valley, read the Thrush & Son® guide to ENERGY STAR 7.0 windows in Ohio for glass choices by zone, then book an estimate and we’ll walk through every rating.
➡️ Schedule in Dayton➡️ View All ServicesCall (937) 833-5136 · 115 Jefferson St, Brookville, OH 45309
- GAF President’s Club Contractor
- Best of Dayton 2024 Winner · 2025 and 2026 Finalist
- BBB Accredited A+
- Since 1960
Further Reading
Official sources: ENERGY STAR Version 7.0 specification, ENERGY STAR climate zone finder, ENERGY STAR testing and certification, NFRC Certified Products Directory and the U.S. Department of Energy.
ENERGY STAR 7.0 FAQ
What does ENERGY STAR 7.0 require for windows in Ohio’s Northern zone?
A U-factor of 0.22 or lower with an SHGC of at least 0.17, or a trade-off pair: a U-factor of 0.23 or 0.24 with an SHGC of 0.35 or higher, or a U-factor of 0.25 or 0.26 with an SHGC of 0.40 or higher.
Is all of Ohio in the Northern climate zone?
No. Montgomery and Miami counties are Northern, but some Ohio River counties, such as Lawrence County, are North-Central. Check yours in the ENERGY STAR climate zone finder.
How do I verify a window meets ENERGY STAR 7.0?
Match the model and glass package on your quote to the NFRC label, then find the same model in the ENERGY STAR Product Finder or the NFRC Certified Products Directory. The ratings should agree and pass your zone.
Which NFRC label numbers count for ENERGY STAR?
Qualification rests on U-factor and SHGC, and the specification caps air leakage. Visible transmittance and condensation resistance help you compare qualifying windows.
Do patio doors follow the same ENERGY STAR 7.0 rules as windows?
No. Doors have their own lines. In the Northern zone, a door with more than half glass needs a U-factor of 0.26 or lower and an SHGC of 0.40 or lower, and the window trade-off rows don’t apply.
Written by Corey Thrush, Vice President and third generation of Thrush & Son®.


Leave a Reply